POST client configuration

The POST client configuration defines where the POST messages are sent from the gateway and must be set to the Boomerang 3 server WIN receiver page.

1. Go to System Configuration -> POST Client to open “POST Client Configuration” form.

2. Check that the checkboxes “Enable Timed Sending”, “Enable Buffered Sending” and “POST Header” are selected and “Connect using SSL” is not.

3. Fill in the “Period” field with 3600. This field defines in seconds how often the gateway by itself communicates with the server and does not affect the nodes period.

4. The “URL” field defines where the POST messages are sent from the gateway and must be set to the Boomerang 3 server WIN receiver page. The content of this field depends on the gateway type and can be found in Boomerang 3 in a gateway definition form as shown in Create gateway in Bommerang 3.

For WIN gateway it is

http://[B3URL]/receiver/win

where [B3URL] is the Boomerang 3 system URL.

In the example the URL is http://weblog.icutech.pl/receiver/winarrow-up-right.

Last updated